• Home
  • About us
  • Services
  • News & Promotion
  • Certification
  • CSR
  • Contact us
  • TAT
  • EN
  • TH

GAS CHROMATROGRAPHY-MASS SPECTROMETRY (GC-MS)

  • Home
  • News & Promotion Technology
  • GAS CHROMATROGRAPHY-MASS SPECTROMETRY (GC-MS)
Liquid borne Particle Counter (LPC)
September 15, 2023
Motorized Optical Microscope for Automated Particle Analysis
September 15, 2023

GAS CHROMATROGRAPHY-MASS SPECTROMETRY (GC-MS)

Published by Marketing at September 15, 2023
Categories
  • Technology
  • News & Promotion
Tags

Agilent 5977B InertPlus MSD Turbo EI with UNITY-xr thermal desorption unit.

Agilent GC 8890/MSD 5977B Turbo EI System

GC-MS is ideally suited to the analysis of many small molecular weight organic compounds. These include; amino acids, organic acids, fatty acids, volatile & semi-volatile organics, and petrochemicals/ hydrocarbons. The ALS laboratory in Pathumthani is currently using this instrument for:

  • identifying and quantifying volatile organic compounds
  • outgassing studies
  • testing for residual solvents
  • evaluating extracts from plastics
  • evaluating contaminants on semiconductor wafers (thermal desorption)
  • Able to identify and quantify VOC in environment (cleanroom or semiconductor shop floor) by air sampling tube

We have two dedicated GC-MS instruments with headspace and liquid autosamplers:

Key Features

  • Equipped with Marke’s Unity with Ultra MFC (mass flow controller)
  • Simultaneous sample tube loading
  • Sample preparation in closed system (Teflon chambers in Binder force flow oven), minimizing leak and cross contamination
  • Enables reliable, leak-free in-oven connections
  • Equipped with Autosampler offers the faster injection time
  • Capable of analyzing minute amounts of organic contaminants
  • Precise and reproducible

Services

To analyze trace amounts of volatile and semi volatile organic compounds

  • Semi volatile organic compounds: Organic residues have the potential to cause various problems including bad contact and corrosion. This analysis detects and identifies organic contaminants such as hydrocarbon or oil residue on casting and stamping alloy parts, flux residues, and adhesives.
  • Volatile organic compounds: When coupled with a Static or Dynamic Headspace setup, it is an excellent tool for analyzing potentially detrimental organic substances that outgas from polymers or adhesives at higher operating temperature.

  • บริษัท เอแอลเอส เทสติ้ง เซอร์วิสเซส (ประเทศไทย) จำกัด
  • : 34/13 หมู่ 15 ตำบล คลองสอง อำเภอ คลองหลวง จังหวัด ปทุมธานี 12120
  • : +66 (0) 2700 9665, +66 (0) 2700 9661, +66 (0) 2700 9662
  • : +66 (0) 2700 9660
  • : Pathumthani@Alsglobal.Com 
© Copyright Alstesting.co.,ltd. Limited All Rights Reserved Designed by Webdesignads.com
      • →
      • Call / โทร
      • Line / เพิ่มเพื่อน